Search
History
FusionPower9000

PowerPOD

FusionPower9000

The Outdoor Power Supply Solution for Large-scale Data Centers

Reliable
Agile
Sustainable
Reliable

Reliable

FusionPower9000
Agile

Agile

FusionPower9000
Sustainable

Sustainable

FusionPower9000

High-Reliability Container, 25-Year Lifespan

Specially designed container with Zone 3 earthquake resistance, Grade 12 wind resistance, IP55 protection, and 2-hour fire resistance.

High-Reliability Container, 25-Year Lifespan

Distributed Architecture, Minimizing Failure Impact

Distributed power supply architecture with one power system per container. Lithium batteries are isolated to ensure ’0’ service risk.

Distributed Architecture, Minimizing Failure Impact
Comprehensive Fire Protection System, Precise Mitigation of Fire Risks

Comprehensive Fire Protection System, Precise Mitigation of Fire Risks

Dual protection system (gas fire extinguishing and water spray) and one-press EPO (Emergency Power Off) button for rapid shutdown to prevent fault propagation.

Full-Link Visual Management

Power and environment, access control, and video surveillance systems are directly connected to the management platform. This enables visualized, manageable, and controllable operations, shifting from reactive to proactive maintenance.

Full-Link Visual Management

Prefabrication and Pre-Testing for Streamlined, High-Quality Delivery

Productized engineering approach with prefabrication and pre-testing. Rigorous testing with 1,000+ cases ensures strict quality control before shipment.

Prefabrication and Pre-Testing for Streamlined, High-Quality Delivery

Delivery Period

28weeks

FusionPower9000

18weeks

High Power Efficiency, Low Carbon, Increased Energy Savings

High-efficiency UPS; Up to 98.4% link efficiency in S-ECO mode. Cold/hot aisle containment optimizes airflow and improves cooling efficiency.

High Power Efficiency, Low Carbon, Increased Energy Savings

Technical specifications

Configuration

Configuration 1 IT-only
(2.4MVA)

Configuration 2 IT+ME (2.4MVA)

Configuration 3 IT+ME (2.4MVA)

Configuration 4 IT+ME+Grid Output Cabinet (2.4MVA)

Length x width x height 12192mm×3495mm
×4150mm
12192mm×3495mm
×4150mm
12192mm×3495mm
×4150mm
12192mm×3495mm
×4150mm
Input power supply Three-phase, four-wire + PE,
380V AC/400V AC/415V AC
50/60Hz⁽¹⁾
Three-phase, four-wire + PE,
380V AC/400V AC/415V AC
50/60Hz⁽¹⁾
Three-phase, four-wire + PE,
380V AC/400V AC/415V AC
50/60Hz⁽¹⁾
Three-phase, four-wire + PE,
380V AC/400V AC/415V AC
50/60Hz⁽¹⁾
ME UPS / 1×600kVA
@MAX
1×600kVA
@MAX
1×600kVA
@MAX
IT UPS 4×600kVA
@MAX
3×600kVA
@MAX
3×600kVA
@MAX
2×600kVA
@MAX
Battery parameter SmartLi 3.0 SmartLi 3.0 SmartLi 3.0 SmartLi 3.0
Power backup time 10min@SOL 10min@SOL 10min@SOL 10min@SOL

Recommendations

FusionPower6000

FusionPower6000

Indoor power supply and distribution system designed for medium- and large-sized traditional building DCs

UPS5000-H

UPS5000-H

For medium- and large-sized DC and industry critical power supply

SmartLi

SmartLi

For medium- and large-sized DCs and industry critical power supply

[1] By default, the nominal capacity and breaker selection are calculated based on the 400 V voltage level. If the voltage of a specific project is low, check whether the current exceeds the specified specification after calculation. Otherwise, derate the nominal capacity.